| Sensing head size |
M18 |
| Type |
Cylinder type (with screw), Shielded |
| Power source |
DC 2-wire models |
| Sensing distance |
5 mm ±10% |
| Setting distance |
0 to 3.5 mm |
| Differential distance |
15% max. of sensing distance |
| Sensing object |
Ferrous metal (Sensitivity lowers with non-ferrous metals.) |
| Standard sensing object |
Iron 30 x 30 x 1 mm |
| Response frequency |
100 Hz (Average value) |
| Power supply voltage |
12 to 24 VDC ripple (p-p) 10% max. |
| Operating voltage range |
10 to 30 VDC |
| Leakage current |
0.8 mA max. |
| Control output (Switching capacity) |
3 to 100 mA |
| Control output (Residual voltage) |
3 V max. (Load current 100 mA max. with cable length of 2 m) |
| Indicator |
Operation indicator (red), Operation setting indicator (green) |
| Operation mode |
NO |
| Polarity |
No polarity |
| Protective circuit |
Output short-cut protection Surge suppressor |
| Ambient temperature (Operating) |
-25 to 70 ℃ |
| Ambient temperature (Storage) |
-25 to 70 ℃ |
| Ambient humidity (Operating) |
35 to 95% RH |
| Ambient humidity (Storage) |
35 to 95% RH |
| Temperature influence |
±20% max. of sensing distance at 23 ℃ in the temperature range of −25 to 70 ℃ |
| Voltage influence |
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range |
| Insulation resistance |
Between charged parts and the case: 5 MΩ min. at 500 VDC |
| Dielectric strength |
Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min |
| Vibration resistance |
Destruction: 10 to 55 Hz, 1.5 mm double amplitude each in X, Y, and Z directions for 2 h |
| Shock resistance |
Destruction: 1000 m/s2 10 times each in X, Y, and Z directions |
| Degree of protection |
IEC: IP67 |
| Connection method |
Prewired M12 smart click connector model (0.3 m) |
| Weight |
Package: Approx. 110 g |
| Material |
Case: Stainless steel (SUS303) Sensing surface: Stainless steel (SUS303) Clamping nuts: Stainless steel Toothed washers: Iron zinc plating |
| Accessories |
Instruction manual |