Filter by:

Price range
0.00 (SAR)
298,221.00 (SAR)
0 298221
VENDORS
Manufacturers

ABB

View as Grid List
Sort by
Display per page

1SBL231001R8800 ABB AFC26-30-00-88 230-240V50Hz 240-260V60Hz Contactor

The AFC26-30-00-88 is a 3-pole - 690 V IEC or 600 V UL contactor withScrew terminals, mainly controlling power circuits up to 11 kW / 400 V AC (AC-3) or 15 hp / 480 V AC UL and 45 A (AC-1) or 45 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 230 ... 240 V AC 50 Hz / 240 ... 260 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
350.00 (SAR) 213.00 (SAR)

1SBN164102R1000 ABB ZLU75 Contact Set

1SBN164102R1000 ABB ZLU75 is a spare part for contacts' set to replace on an UA75 capacitor contactor.
650.00 (SAR) 438.00 (SAR)

1SFN164903R1000 ABB ZL185 Main Contact Kit

1SFN164903R1000 ABB ZL185 Main Contact Kit: 3 pole main contact set for a contactor consisting of fixed contacts, moving contacts, springs and hardware
1,460.00 (SAR) 1,362.00 (SAR)

1SFL491001R4200 ABB A185-30-00 230-240V 50Hz Contactor

A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution applications up to a maximum of 1000 V.Operated with control voltage, versions from 24... 690 AC, 50 and 60 Hz
1,650.00 (SAR) 1,486.00 (SAR)

REM615 IEC ABB Motor protection and control

REM615 is a dedicated motor protection and control relay for protection, control, measurement and supervision of asynchronous motors in the manufacturing and process industry.
34,560.00 (SAR) 32,608.00 (SAR)

1SAM340000R1007 ABB MS132-2.5T Circuit Breaker for Primary Transformer Protection 1.6 ... 2.5 A

The circuit breaker for transformer protection, MS132-2.5T, is a compact 45-mm-wide device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 2.5 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows you to manually connect and disconnect the transformer from the mains thanks to its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class of 10. Further features are temperature compensation, a trip-free mechanism, a rotary handle with a clear switch position indication, and a short-circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks, and terminal spacers are available as accessories.
1,390.00 (SAR) 1,076.00 (SAR)