6ES75152FM020AB0 SIEMENS SIMATIC S7-1500F, CPU 1515F-2 PN 6ES7515-2FM02-0AB0

SIMATIC S7-1500F, CPU 1515F-2 PN, central processing unit with work memory 750 KB for program and 3 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 30 ns bit performance, SIMATIC Memory Card required
Manufacturer: SIEMENS
SKU: PCM752
19,850.00 (SAR)
17,391.00 (SAR)
GET A QUOTE FOR THIS

Why to Shop at faakart.com

  • Standard Delivery*

    We provide standard delivery across the country.

  • Return Policy*

    We provide transparent return and exchange policy, please refer to terms and conditions for details.

  • 100% Genuine Products

    We do not sell anything which is counterfeited or tampered-with in manner, so you can be at ease that purchased product is 100% genuine.

Supply voltage: DC (V)
19.2–28.8
Voltage type of supply voltage
DC
Number of relay outputs
0
Width (mm)
70
Model
Modular
Processing time (1K, binary operation) (ms)
0.03
Number of HW-interfaces industrial Ethernet
2
Number of interfaces PROFINET
2
Number of HW-interfaces: RS-232
0
Number of HW- interfaces: RS-422
0
Number of HW- interfaces: RS-485
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces
0
Number of analogue outputs
0
Number of analogue inputs
0
Number of digital inputs
0
Number of digital outputs
0
With optical interface
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for inter-state safety
No
Supporting protocol for PROFISafe
Yes
Supporting protocol for SafetyBUS
No
Supporting protocol for other bus systems
No
Radio-standard Bluetooth
No
Radio-standard Wi-Fi 802.11
No
Radio standard GPRS
No
Radio-standard GSM
No
Radio-standard UMTS
No
IO link master
No
System accessory
Yes
Redundancy
No
With display
Yes
Types of memory
Other
Memory size (kByte)
3500
Additional program memory is possible
No
Rail mounting is possible
Yes
Wall mounting/direct mounting
No
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
Yes
Performance level according to EN ISO 13849-1
Level e
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
ATEX gas-ex-protection, Cat. 3G
Explosion safety category for dust
None
Height (mm)
147
Depth (mm)
129
SIL according to IEC 61508
3
Product tags