Control power DC input current |
0.8 A |
Internal shunt power |
75 W |
Capacitive energy absorption |
129 J |
Internal shunt resistance |
37.5 Ohm |
Internal capacitance |
585 µF |
Rated power output |
97 W @ 20% |
DC continuous output current to bus |
10.5 A, 3-phase |
Peak output current to bus |
31.6 A, 3-phase |
Main AC input current |
11.2 A @ 324...524V rms, 3-phase |
Peak AC input current |
33.4 A @ 324...524V rms, 3-phase |
Control power current |
4 A @ 24V inrush current |
Continuous output power to bus |
3.5 kW @ nominal 240V rms, 3-phase at 1/2 power, 7.0 kW @ nominal 480V rms, 3-phase. |
Peak output power to bus |
10.5 kW @ nominal 240V rms, 3-phase at 1/2 power, 21.0 kW @ nominal 480V rms, 3-phase. |
Line loss ride through |
20 ms |
Efficiency |
99 % |
AC input frequency |
47 Hz |
Control power DC input voltage |
24V DC (±10%) |
Nominal bus output voltage |
458...747V DC |
Inrush, max |
33 A (zero to peak) |
Bus overvoltage |
832V DC @ 480V, nominal AC input |
AC input voltage |
195...528V rms @ 3-phase (240/480V nom) |
Shunt on |
775V plus 30V x bus regulator capacity/utilization |
Shunt off |