1444-TSCX02-02RB ALLEN BRADLEY Tachometer Signal Conditioner Expansion Module

Tachometer Signal Conditioner Expansion Module for 1444 Series, Inputs: 2 speed, Outputs: 2 TTL speeds, Network:1444 Series Local Bus, Must be connected to a Dynamic Measurement Module, Requires Terminal Base (B) and Removable Plug Connectors.
Manufacturer: Allen-Bradley
SKU: NSRN546
2,456.00 (SAR)
1,819.00 (SAR)
GET A QUOTE FOR THIS

Why to Shop at faakart.com

  • Standard Delivery*

    We provide standard delivery across the country.

  • Return Policy*

    We provide transparent return and exchange policy, please refer to terms and conditions for details.

  • 100% Genuine Products

    We do not sell anything which is counterfeited or tampered-with in manner, so you can be at ease that purchased product is 100% genuine.

Electrical

Rated control supply voltage at DC 18 V
Type of electric connection Spring clamp connection
Rated control supply voltage Us at DC 32 V
Error 1...240 RPM: ± 0.2 RPM, 240...12k RPM: ±2.0 RPM, 12k...20.4k RPM: ±5.0 RPM, 20.4k...120k RPM: ±20 RPM, 120k...360k RPM: ±60 RPM, 360k...1,200k RPM: ±160 RPM
Voltage type for actuating DC
With detachable clamps Yes
Fault Action Update module status indicator
Accuracy ±3° of speed input for 1/rev up to 20 kHz
Fault detection Communication link time-out: 1 second (fixed)
 
 

Certification

With approval according to UL Yes
North American temperature code T4
IEC temperature code T4
 
 

Environmental

Surrounding air temperature, max 70 °C
Operating temperature -25 °C
Emissions IEC 61000-6-4
Relative humidity 5...95% noncondensing
ESD immunity 6 kV contact discharges, 8 kV air discharges
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2 kV line-earth (CM) on shielded signal ports
EFT/B immunity ±2 kV at 5 kHz on shielded signal ports
Conformal coating All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Conductor/insulation temperature rating, min 85 °C
Operating temperature (spring type only), max 105 °C
Operating temperature (screw type only), max 115 °C
Nonoperating temperature -40 °C
 
 

Terminal Pin Connectors

Drive current 5 mA per output
Protection Short circuit protected
EMC ESD/EFT/Conducted Immunity
Distance Wire lengths to 30 m
Function Raw signal output
Impedance 680 Ω output impedance, 1.5k Ω return resistance for ESD protection of direct, discharges to BNC connector shell
Number of terminal pin connectors 4
 
 

Local Bus Outputs

Signal TTL speed (once-per-rev)
Power Passes power from each main module (1444-DYN04-01RA) to its expansion modules, Power is not passed between main modules, When redundant power supplies are connected to a main module, only the voted power source is distributed to its expansion modules.
Number of local bus outputs 2
Type Opto-isolated open-collector
Connections Integral, via ribbon connector
Capacity Can serve six main modules (1444-DYN04-01RA) (minimum)