Parker Instrumentation CT Series Tee Fitting, 9/16" x 9/16" x 9/16", F562C High Pressure Coned-and-Threaded x F562C High Pressure Coned-and-Threaded x F562C High Pressure Coned-and-Threaded, 60000 PSI, Cold Worked 316 Stainless Steel, Straight, Tee.
Pneumatic connection, port 1; male thread R1/8
Pneumatic connection, port 2 For tubing outside diameter of 4 mm
Temperature-dependent operating pressure: -0.95 bar to 14 bar
Ambient temperature: -10 °C to 80 °C
Nominal size: 3 mm
Pneumatic connection 1: External thread R3/8
Pneumatic connection 2 for pneumatic tubing outside diameter 6 mm
Temperature-dependent operating pressure: -0.95 bar to 14 bar
Ambient temperature: -10 °C to 80 °C
Nominal width: 5 mm
Valve function Flow control function
Standard nominal flow rate in flow control direction 105 l/min
Pneumatic connection 1 M5
Operating pressure: 0 bar to 10 bar
Adjusting the Knurled screw
Piston diameter: 32 mm
Theoretical force at 0.6 MPa (6 bar, 87 psi), advance stroke 483 N
Stroke: 500 mm
Cushioning Pneumatic cushioning, adjustable at both ends Shock absorber, hard characteristic curve
Position detection Via proximity switch
Piston diameter: 32 mm
Theoretical force at 0.6 MPa (6 bar, 87 psi), advance stroke 483 N
Stroke: 10 mm–3000 mm
Cushioning : Pneumatic cushioning, adjustable at both ends Shock absorber, hard characteristic curve
Position detectionVia proximity switch
Pneumatic connection, port 1; Male thread R3/8
Pneumatic connection, port 2 For tubing with an outer diameter of 12 mm
Temperature-dependent operating pressure: -0.95 bar to 14 bar
Ambient temperature: -10 °C to 80 °C
Nominal size: 11 mm
Valve function: Exhaust air one-way flow control function
Standard nominal flow rate in flow control direction: 160 l/min
Pneumatic connection, port 1 QS-4
Adjustment component: Knurled screw
Pneumatic connection 1: External thread R3/8
Pneumatic connection 2 : for pneumatic tubing outside diameter 8 mm
Temperature-dependent operating pressure: -0.95 bar to 14 bar
Ambient temperature: -10 °C to 80 °C
Nominal width: 6.7 mm
690431950B0BF0P00A400
AC DRIVE
690+ SERIES
400-460 V
3-PHASE
4 KW
9.5 AMP OUTPUT CURRENT
FRAME B
BRAKE SWITCH FITTED
FILTER FITTED
NO SYSTEM BOARD
PANEL MOUNT
ENGLISH (50 HZ)
6901 KEYPAD FITTED
NO COMMS
ACH580 HVAC drive offering has all key features built-in to control fans, pumps and compressors, and more complex equipment like air-handling units and chillers, ensuring smooth, energy-efficient operation of your HVAC systems in normal and mission-critical situations. The built-in features significantly reduce installation time and the intuitive control panel with an HVAC-specific primary settings menu and help assistants makes startup, commissioning and operation easy. The optional Bluetooth® capability enables the commissioning and monitoring of the drive from a distance. The ACH580-01 comes in IP21 enclosure and can be installed on the wall as standard. Also, IP55 and flange mounting units are available.
Filter-pressure regulator Festo LFR-1/2-D-MAXI-MPA is a combination of compressed air preparation devices without an oil sprayer. For this equipment, the Festo line has a modern alternative: air treatment units of the MSB series.
Mode of operation: Double-acting
Piston diameter: 32 mm
Theoretical force at 6 bar, advancing 483 N
Stroke: 80 mm
Cushioning Pneumatic cushioning, adjustable at both ends
Valve function Unlockable, non-return function
Pneumatic connection 1: G1/4
Pneumatic connection 2 G2
Operating pressure: 0.5 bar to 10 bar
Type of mounting: Screw-in with an external thread
Pneumatic connection 1: For pneumatic tubing outside diameter 6 mm
Pneumatic connection 2 : for pneumatic tubing outside diameter 6 mm Temperature-dependent operating pressure: -0.95 bar to 14 bar
Ambient temperature: -10 °C to 80 °C
Nominal width: 4.3 mm
Mode of operation: Double-acting
Piston diameter: 25 mm
Theoretical force at 0.6 MPa (6 bar, 87 psi), advance stroke : 295 N
Stroke 50 mm
Cushioning: Elastic cushioning rings/plates at both ends