SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure . Type of explosion protection: Intrinsic Safety Connection thread el.: 1/2" NPT / pneu.: 1/4" NPT without limit monitor without option module . Brief instructions German / English / Chinese . with mounted pressure gauge made of plastic, IP31, aluminum block, 1/4" NPT aluminum block, 1/4" NPT
product phase-out !!! the preferred successor is 3RQ4018-2AM08-0AA0 output coupler relay coupler, 1 CO, 24 V DC operating range 0.7...1.25 x Us enclosure width 6.2 mm spring-loaded terminal (push-in) thermal current 6 A (see derating characteristic curve)
MICROMASTER 420 without filter 380-480 V 3 AC +10/-10% 47-63 Hz Constant torque 0.75 kW Overload 150% for 60s Square-law torque 0.75 kW 173x 73x 149 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without AOP/BOP
residual current device RCD520B basic RCD type B or B+ loadside mounted rated
resid. current 0.03...5 A adjustable tv 0...10,000 ms 4-pole In=160 A Ue=127-690 V
accessory for: 3VA11
Power contactor, AC-3 17 A, 7.5 kW / 400 V 110 V AC, 50/60 Hz 3-pole, 2 NO + 2 NC, Size S0 Screw terminal !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2025-1AG24<<
Wiring kit Electrical and mechanical For reversing starter size S0 !!! Phased-out product !!! Successor is SIRIUS 3RA2 Preferred successor type is >>3RA2923-2AA1<< Notes Sucessor:The successor is 3RA2923-2AA1
Enclosure for command devices, 22 mm, round, Enclosure material plastic, enclosure top part gray, 3 control points plastic, Recess for labels, without equipment
The MS132-10-HKF1-11 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 10.0 A and a pre-assembled front mounted auxiliary contact HKF1-11. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.