Manufacturers

ALL CATEGORIES

View as Grid List
Sort by
Display per page

DI522A IFM Compact evaluation unit for speed monitoring DIA3010-ZPKG/US/3D/5S

Speed monitor; Nominal voltage DC [V] : 10...36; Protection class : III; Reverse polarity protection : yes; Total number of outputs : 1; Electrical design : PNP; Output function : normally open; Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 250; Short-time current rating of switching output [mA] : 250; Short-circuit proof : yes; Overload protection : yes; Sensing range [mm] : 10; Sensing range adjustable : no; Operating distance [mm] : 0...8.1; Setting range [Imp/min] : 5...3600; Correction factor : steel: 1; stainless steel: 0.7; brass: 0.5; aluminum: 0.4; copper: 0.3; Hysteresis [% of Sr] : 10; Start-up delay [s] : 5; Max. damping frequency [Imp/min] : 18000; Adjustment of the switch point : multiturn potentiometer; Ambient temperature [°C] : -25...60; Storage temperature [°C] : -25...60; Mounting : flush mountable; Thread designation : M30 x 1.5; Materials : brass special coating; PA; stainless steel; TPE-U; Items supplied : lock nuts: 2
1,500.00 (SAR) 1,229.00 (SAR)

R900924021 Rexroth Hydraulikventil 4WE6EA62/EW230N9K4

R900924021 Rexroth Hydraulikventil 4WE6EA62/EW230N9K4
450.00 (SAR) 304.00 (SAR)

148VK-0281-030 AC Fan

AC Fan Salt Fog Axial Ball Bearing 220V 212CFM/248.04CFM 53dB/57dB 172 X 150 X 38.3mm
1,654.00 (SAR) 1,275.00 (SAR)

S4D400-AP12-37 230VAC, 135W, 0.76A, φ400mm AC axial Fans S4D400AP1237

Brand HRSTAR Voltage 230 Volts Wattage 135 watts Cooling Method Air Material Alloy Steel, Plastic Maximum Rotational Speed 1450 RPM
1,800.00 (SAR) 1,598.00 (SAR)

IS-12-H5-S2 DATALOGIC short double range non flush 95B062771

ø12 short: double range non flush 8mm; PNP NO + NC 3 wires; M12 IS-12-H5-S2 = ø12 short - double range non flush 8mm - pnp no + nc 3 wires - M12
250.00 (SAR) 146.00 (SAR)

SLG10S-050SAR11A00 SICK LIGHT GRID 1120074

SICK Switching automation light grids, SLG-2, SLG10S-050SAR11A00, Communication interface: IO-Link, Sensing range, parallel beam (recommended): 440 mm ... 3,500 mm, Standard version, Beam separation: 10 mm, Optical light exit: Slim, Detection height: 500 mm, Connection type: Cable with M8 male connector, 4-pin, Factory setting, beam function: Parallel beam, Factory setting, pin 2 (MF): Teach-in input, Factory setting, pin 4 (OUT): Object detection output = “HIGH”, Factory setting, IO-Link (process data): QL/Qint Status, System status, Beam status, Factory setting, teach-in (default): Auto teach-in
5,823.00 (SAR) 5,306.00 (SAR)